| Customization: | Available |
|---|---|
| Phase: | Single Phase |
| Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| ITEM | MODEL | RXG6K(T) | RXGC6KS(T) | RXG10K(T) | RXG10KS(T) |
| Capacity | VA / Watts | 6KVA/5.4KW | 6KVA/4.8KW | 10KVA/9KW | 10KVA/8KW |
| Input | Normal Voltage | 220VAC, L+N+G | |||
| Input Voltage Range | 100- 280±5V while load≤50% | ||||
| 150-280±5V, while 50%<load≤80% | |||||
| 160-280±5V, 80%<load≤90% | |||||
| 175-280±5V while load>90% | |||||
| Frequency Range | 50/60±10% | ||||
| Input Power Factor | >0.99(220VAC,full R load) | ||||
| Generator | Support generator input(Generator rating≥2*UPS rating | ||||
| Output | Voltage Range | 220VAC+-1% | |||
| Frequency Range | 48Hz/54Hz(AC mode), 50HzX(1±0.1%)(Battery mode) | ||||
| Waveform | Pure Sine Wave | ||||
| Transfer Time | 0 ms | ||||
| Distortion (Full Load) Linear Load | < 3% | ||||
| Distortion (Ful l Load) Nonlinear Load | < 5% | ||||
| Overload Capacity | 105%~125% ,1min then transfer to bypass and alarm. 125%~150% 30s then transfer to bypass and alarm,1min then cut off output. >150% ,0.5s then transfer to bypass and alarm. | ||||
| Load Peak Ratio | 3:1(max) | ||||
| 192VDC Battery PacK | MODEL | RBP167 | N/A | RBP167 | N/A |
| Type | Maintenance free valve regulated lead acid (VRLA) battery | ||||
| Battery Voltage | 192VDC | 192VDC | 192VDC | 192VDC | |
| Battery Capacity | 16*7AH | External | 16*7AH | External | |
| Around backup time (Full load) | 4Mins | Depended on battery capacity | 3Mins | Depended on battery capacity | |
| Around backup time (Half load) | 12Mins | Depended on battery capacity | 9mMins | Depended on battery capacity | |
| Recharge Time | 7 hours to 90%capacity | Depended on battery capacity | 7 hours to 90%capacity | Depended on battery capacity | |
| 240VDC Battery Pack | MODEL | RBP207 | N/A | RBP207 | N/A |
| Type | Maintenance free valve regulated lead acid (VRLA) battery | ||||
| Battery Voltage | 240VDC | 240VDC | 240VDC | 240VDC | |
| Battery Capacity | internal 20*7AH | External | internal 20*7AH | External | |
| Around Backup Time (Full Load) | 7Mins | Depended on battery capacity | 5Mins | Depended on battery capacity | |
| Around Backup Time (Half Load) | 20Mins | Depended on battery capacity | 13mMins | Depended on battery capacity | |
| Recharge Time | 8 hours to 90%capacity | 5Amp charger | 8 hours to 90%capacity | 5Amp charger | |
| LED Display | LED | Load level / Battery level / Battery mode / Line mode / Inverter /B ypass /Over load / Fault | |||
| LCD Display | Option | BAT VDC and % , Input VAC and HZ , Output VAC and HZ, Load W and % ,Temp.Fault Code | |||
| Audible Alarm | Battery Mode | Beeping every 4 seconds (re-settable) and every second when battery | |||
| Overload | Beeping twice every second | ||||
| UPS Fault | Beeping Continuously | ||||
| Bettery Low/Charger Fault | Beeping every 1 second | ||||
| Bypass Mode | Beeping every 2 min | ||||
| L/N Inverse | Beeping every 2 min | ||||
| Communications | RS-232 Interface | With monitoring software. USB Option | |||
| working Environment | Working Temperature | ,- 20ºC~40ºC | |||
| Humidity | 0-95% non-condensing | ||||
| UPS | Product Size WxDxH (mm) | 483 x 600 x 132(3U) | 483 x 600 x 132(3U) | 483 x 600 x 132(3U) | 483 x 600 x 132(3U) |
| Package Size WxDxH (mm) | 795*590*330 | 795*590*330 | 795*590*330 | 795*590*330 | |
| Gross Weight(Kg) | 27 | 28.5 | 34 | 35 | |
| RBP167 BAT Pack | Product Size WxDxH (mm) | 483 x 600 x 132(3U) | N/A | 483 x 600 x 132(3U) | N/A |
| package Size WxDxH (mm) | 795*590*330 | N/A | 795*590*330 | N/A | |
| Gross Weight(Kg) | 65 | N/A | 65 | N/A | |
| RBP207 BAT Pack | Product Size WxDxH (mm) | 483 x 600 x 132(3U) | N/A | 483 x 600 x 132(3U) | N/A |
| package Size WxDxH (mm) | 795*590*330 | N/A | 795*590*330 | N/A | |
| Gross Weight(Kg) | 74 | N/A | 74 | N/A | |
| optional functions | ECO | optional | |||
| EPO | optional | ||||
| SNMP | optional | ||||
| REMARK | RXG*K--- Standard Type, RXG*KS---- Long Time Type | ||||
| Option | Convertor for Option | ||||