Nature of Source Flow: | Active Inverter |
---|---|
Phase: | Single |
Output Power: | 110 / 120V/ 220V/230V ±5% |
Brand: | Kemapower |
Type: | DC/AC Inverters |
Power Source: | Solar Power |
Customization: |
---|
Suppliers with verified business licenses
Model | ZYSW-1000TS | |
Maximum Output Power(W) | 1000VA | |
800W | ||
Input | Voltage | UPS.mode:145-270±5(Vac) |
INV.mode:100-290±5(Vac) | ||
Frequency | 45-65Hz | |
Output | voltage (AC mode) |
UPS.mode:203-238±5(Vac) |
INV.mode:150-255±5(Vac) | ||
voltage (Battery mode) |
220±10(Vac) | |
Frequency | 50Hz ±0.5Hz (DC mode) | |
Output Waveform | Pure sine wave | |
General Protection | Output Short; Over Voltage; Low-Voltage; Power Utility Short; Low Battery Voltage | |
DC voltage | 12VDC | |
Charge Current | 10A/20A for selection | |
Battery | Battery Type | GEL, lead-acid , Open lead-acid battery |
600-1200 | 12VDC External | |
Grid Charge current | 10A/20A for selection | |
Solar charge controler | Max 50A ( adjustable) | |
Transfer Time(ms) | Max 10MS | |
Max 10MS | < 150% overload:No beed, > 150% overload :1beep per second | |
Alarm | battery low,LCD type beeping every 0.5second, when overload:UPS beep every 0.5second |
|
Communication Interface | USB communication option. | |
LCD Display | I/P O/p vac hz, bat % , load %, input range / battery type /charge current/ grid or bat priority selections, solar charge vdc amp , fault , over temp | |
Product size | WxDxH (mm) | 290×307×123 |
Operating temperature | 0~40ºC | |
Humidity | 10%~90% no condensing | |
CTN size | WxDxH (mm) | 355*380*233 |
CTN Weight (Gross/Net) (KG) | 11.65/10.9 |