Customization: | Available |
---|---|
Phase: | Single Phase |
Type: | On-line |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Item | Model | XG6K-TXB | XG6KL-TX | XG10K-TXB | XG10KL-TX |
Capacity | VA / Watts | 6KVA/5.4KW | 6KVA/4.8KW | 10KVA/9KW | 10KVA/8KW |
Input | Normal voltage | L+N+G=220VAC or L1110+L2 110=220V | |||
Turn on Voltage range | (120+-5~274+-5)VAC | ||||
Frequency range | 40~60Hz+-0.2(adjustable) | ||||
Input power factor | >0.99(220VAC,full R load) | ||||
Generator | Support generator input(Generator rating≥2*UPS rating ) | ||||
line low loss/comeback | 220VAC:(120±5)VAC/(140±5)VAC when Load≤50% | ||||
220VAC:(150±5)VAC/(165±5)VAC when 50%< Load≤80% | |||||
220VAC:(160±5)VAC/(180±5)VAC when 80%< Load≤90% | |||||
220VAC:(175±5)VAC/(190±5)VAC when Load>90% | |||||
Output | Voltage range | 200VAC/208VAC/220VAC/230VAC/240VAC, need confirm before order(Could be adjusted by software,10% derating for 208VAC/200VAC) | |||
Frequency range | 40~60Hz+-0.2(adjustable) | ||||
Wave form | PureSineWave | ||||
Transfer time | 0 ms, Between Line mode and Bat mode | ||||
Transfer time: 4ms (typical2.5ms), line Mode and bypass mode | |||||
Voltage distortion | ≤6%,Full RCD load | ||||
Voltage distortion | ≤2%,Full R load | ||||
Overload capacity | ≤105%+-5% warning only, 105%+-5%<Load≤125% +-5%1ms to bypass ; 125%±5%<load≤135%±5% 30S to bypass,Load>135%±5% 100MS to bypass | ||||
Load peak ratio | 3:1(max) | ||||
Battery | Battery Type | Maintenance free valve regulated lead acid (VRLA) battery | |||
Battery voltage | 192VDC | ||||
Battery capacity | 16*7AH | External | 16*9AH | External | |
Recharge time | 7 hours to 90% capacity | Depended on battery capacity | 7 hours to 90% capacity | Depended on battery capacity | |
Charge Current | 1A | Normal 5Amp. Max 7Amp | 1A | Normal 5Amp. Max 7Amp | |
Display | LED Mode | Load level / Battery level / Battery mode / Line mode / Inverter , Bypass ,Over load , Fault | |||
LCD Mode | LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. Fault Code ,LED for line,bat, Inverter, Bypss,Fault | ||||
Audible Alarm | Battery Mode | Beeping every 4 seconds (re-settable) and every second when battery low | |||
Overload | Beeping twice every second | ||||
Fault | Beeping Continuously | ||||
Bettery low/charger fault | Beeping every 1 second | ||||
Bypass mode | Beeping every 2 min | ||||
L/N inverse | Beeping every 2 min | ||||
Communications | RS-232/USB Interface |
With monitoring software | |||
Working Environment | Surge protection | RJ-45 I/O port available for network or Fax/Modem | |||
Working temperature | - 20ºC~40ºC | ||||
Humidity | 0-95% non-condensing | ||||
Product size | WxDxH (mm) | 540*260*720 | 260*533*560 | 540*260*720 | 260*533*560 |
Product Weight | Kg | 85 | 53 | 93 | 55 |
PCS/CTN | 1 | 1 | 1 | 1 | |
CTN size | WxDxH (mm) | 730*440*1000 | 360*640*760 | 730*440*1000 | 360*640*760 |
CTN Weight(G/W) | Kg | 94 | 62 | 102 | 64 |
REMARK | XG*K-TX --- Standard Type Internal battery with Transformer, XG*KL-TX Long Time Type With Transformer,External battery |