Item |
Model |
XG1K-RTXB |
XG1KS-RTX |
XG2K-TXB |
XG2KS-TX |
XG3K-TXB |
XG3KS-TX |
Capacity |
VA / Watts |
1KVA / 0.9KW |
1KVA/0.8KW |
2KVA/1.8KW |
2KVA/1.6KW |
3KVA/2.7KW |
3KVA/2.4KW |
Input |
Normal Voltage |
220VAC or 110VAC |
Turn on Voltage Range |
(90±5~300±5)VAC or ( 60+-5-138+-5)VAC |
Frequency Range |
40~60Hz(adjustable) |
Input Power Factor |
0.99(220VAC,full R load) |
Generator |
Support generator input(Generator rating≥2*UPS rating ) |
Line Low Loss/Comeback |
220VAC:(110±5)VAC/(125±5)VAC when30%<load≤60%, 110VAC:(60±3) VAC /(75±3) VAC when load≤60% |
220VAC:(120±5) VAC /(135±5) VAC when60%<load≤70%,110VAC:(70±3) VAC /(75±3) VAC when60%<load≤70% |
220VAC:(140±5) VAC /(155±5) VAC when70%<load≤80% , 110VAC:(70±3) VAC /(85±3) VACwhen70%<load≤80% |
220VAC:(160±5) VAC /(170±5) VAC when load>80%, 110VAC:(80±3 VAC /(85±3) VAC when load>80% |
(300±5)VAC/(285±5)VAC when 0%≤load<100% |
Output |
Voltage Range |
200VAC/208VAC/220VAC/230VAC/240VAC/110VAC/120VAC, need confirm before order |
Frequency Range |
50Hz or 60HZ+-0.2Hz(Battery mode) |
Wave form |
Pure Sine Wave |
Transfer Time |
0 ms, Between Line mode and Bat mode |
Transfer time: 4ms (typical 2.5ms), line Mode and bypass mode |
Distortion |
≤4%,Full R load |
Degree Of Distortion |
≤7%,Full RCD load |
Overload Capacity |
100%±5%<load warning only, 125%±5%<load≤150%±5% 30s ;105%±5%<load≤125%±5% 60S; load>150%±5%, 300MS to bypass |
Load Peak Ratio |
3:1(max) |
Battery |
Battery Type |
Maintenance free valve regulated lead acid (VRLA) battery |
Battery Voltage |
36VDC |
36VDC |
72VDC |
72VDC |
72VDC |
72VDC |
Battery |
3*7AH |
External |
6*7AH or 9AH |
External |
6*7AH or 9AH |
External |
Recharge Time |
5 hours to 90%capacity |
Depend on battery |
5 hours to 90%capacity |
Depend on battery |
5 hours to 90%capacity |
Depend on battery |
Charge Current |
1A |
5Amp,Max 7Amp |
1A |
5Amp,Max 7Amp |
1A |
5Amp,Max 7Amp |
Display |
LED Display |
Line / Inverter , Bypass ,Battery |
LCD Display |
input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp.LCD For input output HZ/VAC, Bat %/VDC, Load % and VA/Watts,Temp. LED for line,bat, Inverter, Bypss |
Protection |
Overload, over Temp, Short Circuit , Over Charge, Over discharge |
Audible Alarm |
Battery Mode |
Beeping every 4 seconds (re-settable) and every second when battery low |
Overload |
Beeping every 1 min |
Fault |
Beeping every 1 min |
Bettery Low/Charger Fault |
Beeping every 1 min |
Bypass Mode |
Beeping every 2 min |
L/N Inverse |
Beeping every 2 min |
Communications |
RS-232/USB Interface |
With monitoring software |
Working Environment |
Surge Protection |
RJ-45 I/O port available for network or Fax/Modem |
Working Temperature |
0ºC~40ºC |
Humidity |
0-95% non-condensing |
Product size |
WxDxH (mm) |
400*180*260 |
350*145*230 |
465*210*328 |
430*190*328 |
465*210*328 |
430*190*328 |
Product Weight |
Kg |
19.5 |
28 |
37 |
25 |
39 |
27 |
PCS/CTN |
|
1 |
2 |
1 |
1 |
1 |
1 |
CTN size |
WxDxH (mm) |
530*295*390 |
495*470*340 |
600*325*455 |
570*305*450 |
600*325*455 |
570*305*450 |
CNT G/W |
Kg |
20.5 |
30 |
38.5 |
26 |
40.5 |
28.5 |
REMARK |
XG*K-TXB --- Standard Type Internal battery And Transformer , XG*KS-TX---- Long Backup Type With Transformer,External battery |