TB Low Frequency Online UPS (TB10K-30K)
Over 15 years ago, we are in the Electronic and Electrical field specializing in manufacturing and supplying
Backup power solution:UPS, HOME UPS, Battery, inverter, Inverter with Charger, AVR
Solar Power Solution: Solar Charger Controller, Solar Power Inverter, Solar Battery, Solar Street lamp
Also to sell DC Light, DC Fan, DC TV and so on
we have Factory in Foshan and Ningbo Cty. Foshan to make Electric product and battery. Ningbo to make PV panel .
Key features
1. Three phase in, one phase out
2. Microprocessor control
3.100% unbalance protection design
4. True on-line double conversion design providing all power protection
5. Isolated output
6. Sine wave pulse width modulation
7. IGBT inverter design.
8. Wide Input voltage windows
9. Pure sine wave output less than 3% THD
10. Expandable battery run time
11. Generator compatible
12. Cold start
13. Load/Battery power meter display
14. Overload, on-line, battery status LED/LCD
15. Advanced Battery Management
16. Automatic charging in UPS off mode
17. Smart RS-232 communication port
18. Optional SNMP card
Capacity:
* TB10kVA/8KW/ 192VDC/6A,
* TB15kVA/12KW/192VDC/6A,
* TB20kVA/16KW/192VDC/6A,
* TB30kVA/24KW/384VDC/20A,
Technical Specifications
MODEL |
TB10K |
TB15K |
TB 20K |
TB30K |
Power Capacity |
10KVA |
15KVA |
20KVA |
30KVA |
8KW |
12KW |
16KW |
24KW |
Input |
Voltage Range |
380V±20%(3 phase) or 205V±20%(3 phase) |
Frequency |
50Hz±5% or 60Hz±5% |
Phase |
3 Phase + GND |
Output |
Voltage Range |
220V±1% or 110VAC ±1% |
Phase |
Single phase + GND |
Frequency |
50 (60)Hz ± 0.3% |
Waveform |
Pure sine wave |
Overload Capacity |
Overload 125% for 10 Mins, 125%-150% for 30s .automatically resume when load become normal |
Power factor |
0.8 |
THD |
< 3%(linear load), < 5%(nonlinear load) |
Battery |
Battery Type |
Sealed lead acid, maintenance free |
DC Voltage |
192VDC |
384VDC |
Max Charge Current |
10A |
6~30A |
Efficiency |
Whole unit |
>85% |
Transfer Time |
0ms |
Panel Indication |
LCD |
Input,oupt,battery voltage,frequency,load rate,UPS state, temperature |
LED |
Main input , bypass,Inverter,Battery,Over load,Fault |
Environment |
Temperature |
0~40ºC |
Humidity |
0~95%(non condensing) |
Noise |
<58dB(1m) |
Communication |
Interface |
RS232 |
Software |
1.Power status 2.UPS shutdown 3.Monitor UPS status 4.UPS self test 5.Auto-save files |
Product size(mm) |
700*365*950 |
780*580*1170 |
product weight(Kg) |
88 |
155 |
155 |
300 |
Package size(mm) |
780*430*1110 |
945*745*1395 |
Package weight(Kg) |
98 |
165 |
165 |
350 |
Product Show:
* I/P: Three Phase, wire voltage 380V/ 205V , O/P:220VAC or 110VAC ± 1%
* Capacity:10K/12K/15K/20K/30K/40KVA
* Output PF: 0.8
* Wave Form:Pure sine wave
* Transfer Time:0 ms
* DC Voltage: 10/12/15/20KVA:192VDC,30/40KVA:384VDC
* Bat.:External Batterys
* Charge Current: 10/12/15/20KVA:10A,30/40KVA:6-30A adjustable
Certifcates Display
Sales And Engineer Display